In this article, electrical engineer, Peter J. Ford, P.E., provides an introduction to the basics of electricity. He discusses voltage, resistance, current, and how each variable affects the injury…
Marinas and boatyards have numerous day to day hazards not found in many other publicly accessible areas. Electric Shock Drowning (ESD) is an example of one such hazard.
This article explains the hazards and marine industry standards that apply to the electrical utilities on docks, shore power cables, and boat electrical systems.

ESD occurs when a swimmer encounters an electrical current in the water that is sufficient to cause muscle paralysis.
There is no visible indication of the electrical current being present in the water. A person can very easily go from feeling a strange tingling sensation and then a few feet later become completely paralyzed. This silent and unseen hazard claims lives every year around private docks and marinas.
The amount of current that can cause an ESD is very low. The standards for vessels and marinas only allow between 4 and 30 milliamperes leakage before breakers and other devices trip, depending on the application. For context, a common household circuit breaker is rated at 15 amperes which is 15,000 milliamperes, and a cell phone charging draws between 1,000 and 5,000 milliamperes.
The source of the ESD hazard starts with AC power that is common on docks and in marinas across the country. While electrical leakage from vessels is the most common source involved in ESD, dock utilities can also be a source.
The AC power is run on docks to power many different systems, including:
Electricity seeks to return to its source to complete the circuit, and a greater amount of current will flow in a path with less resistance to achieve that. When the systems on the dock and/or vessel are all functioning properly, the electricity will return through the shore power cable and the dock’s utility cable with very little current returning though other paths.
When there is a fault somewhere in these systems, leakage electrical current will return through alternative paths which can be through the water. The ESD hazard can occur in fresh, brackish, and salt waters.
Because the considerations and requirements for marinas and vessels are so different, the standards for each are handled by separate bodies. The electrical standards for marinas are covered by the National Fire Protection Association (NFPA), and the American Boat & Yacht Council (ABYC) addresses the standards for electrical systems aboard recreational vessels.
A common practice for any marina should be conducting a regular “dock walk.” These dock walks allow the marina personnel to identify and address hazards around the facility.
To combat the ESD hazard, attention needs to be paid to the electrical utility cables and shore power cable connections. A check ensuring that the correct amperage type shore power cords and/or adapters are used at every connection point is an easy measure to guard against the electrical faults that can create the ESD hazard.
To help in reducing the exposure to the possible ESD hazards, it is recommended that marinas prohibit swimming in the waters around docks. This policy needs to be supported with proper signage around the marina informing people of the restriction for it to be effective.
Vessel electrical systems range from simple to complex depending on the size, type, and age of the vessel.
Most vessels are equipped with both DC and AC electrical systems. Care must be taken in the electrical wiring aboard, especially if there are any modifications made to these systems, so that there is no connection between them and that proper grounding is maintained. A fault in the AC electrical system can lead to electrical leakage and an ESD hazard.
Shore power cables are equipped with features intended to prevent the mismatch of amperage types plugs and outlets, but if the features are defeated in some way it can create the potential for an ESD hazard. There are adapters available that will allow for different amperage types of cable and plugs to be connected safely.
Docks, marinas and vessels with AC power can be hiding a hazard that the public may not be aware of. Investigation of ESD can involve experts specializing in marina accident reconstruction, recreational boating, electrical systems, electrical engineers or experts who specialize in marina and boatyard operations.
For more information, submit an inquiry or call us at 800.813.6736.
In this article, electrical engineer, Peter J. Ford, P.E., provides an introduction to the basics of electricity. He discusses voltage, resistance, current, and how each variable affects the injury…
This article discusses the process by which it is possible to reconstruct an incident by examining injury data. In this instance, our biomedical engineer was tasked with determining the manner in…
Robson Forensic sponsored a research study on drowning incidents in marina waters. The study focused on incidents concerning persons unintentionally falling into the waters of a marina and…